Customer challenge:

  • Monitoring of sensors and remote control of equipment. Reduction of required network traffic.

7SEAS Solution:

  • TCP/IP module with 8 digital inputs (pull-up) and 4 open-collector outputs.
  • Module reports alert only when there is a change in the state of the inputs.
  • RJ45 Ethernet connection.
  • Class A CE certification.
  • Operation in client mode, connecting to a predefined server, with the possibility of changing the IP of the client and the server.
  • Module configuration via TCP/IP.

Key competences involved:

  • System architecture and technological solution.
  • Printed circuit design and selection of electronic components optimized for CE certification, with low electromagnetic radiation and high electromagnetic immunity.
  • Hardware/firmware developed from scratch.